UniWave Electric UniWave Electric

Cnjuho MCCB by Cartons Gv2me Molded Case Circuit Breaker MPCB

Product Description

1. Application
GV2ME Molded Case Circuit Breaker MPCB
GV2P Series motor protecting breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.
2. Main parameter
Type Rated standard power of 3-phase motors 50/60HZ in category AC-3 Setting range(A)
220V 380V 415V 440V 500V 660V
KW KW KW KW KW KW
GV2P01 -- -- -- -- -- -- 0.1-0.16
GV2P02 -- -- -- -- -- -- 0.16-0.25
GV2P03 -- -- -- -- -- -- 0.25-0.4
GV2P4 -- -- -- -- -- 0.37 0.4-0.63
GV2P05 -- -- -- 0.37 0.37 0.55 0.63-1.0
GV2P06 -- 0.37 -- 0.55 0.75 1.1 1.0-1.6
GV2P07 0.37 0.75 0.75 1.1 1.1 1.5 1.6-2.5
GV2P08 0.75 1.5 1.5 1.5 2.2 3 2.5-4.0
GV2P10 1.1 2.2 2.2 3 3.7 4 4-6.3
GV2P14 2.2 4 4 4 5.5 7.5 6.0-10.0
GV2P16 3 5.5 5.5 7.5 7.5 9 9.0-14.0
GV2P20 4 7.5 9 9 9 11 13.0-18.0
GV2P21 5.5 11 11 11 11 15 17.0-23.0
GV2P22 5.5 11 11 11 15 18.5 20.0-25.0
GV2P32 7.5 15 15 15 18.5 26 24.0-32.0
GV3P06 -- 0.37 -- 0.55 0.75 1.1 1.0-1.6
GV3P07 0.37 0.75 1.1 1.1 1.1 1.5 1.6-2.5
GV3P08 0.75 1.5 1.5 1.5 2.2 3 2.5-4.0
GV3P10 1.1 2.2 2.2 3 3.7 4 4.0-6.0
GV3P14 2.2 4 4 4 5.5 7.5 6.0-10.0
GV3P20 4 7.5 7.5 7.5 10 11 10.0-16.0
GV3P25 5.5 11 11 11 15 18.5 16.0-25.0
GV3P40 11 18.5 22 22 25 33 25.0-40.0
GV3P63 15 30 33 33 40 55 40.0-63.0
GV3P80 22 40 45 45 55 63 56.0-80.0
Production & Certificates
3. We commit:
Molded Case Circuit Breaker MPCB Commitment
3. Office and working department,
Molded Case Circuit Breaker MPCB Office
5. Certificate:
Molded Case Circuit Breaker MPCB Certificate
6. Shipping:
Molded Case Circuit Breaker MPCB Shipping
Frequently Asked Questions (FAQ)
Q What is the primary application of GV2P and GV3P series motor protecting breakers?
They are mainly used for overload and short circuit protection of motors in AC 50/60Hz, up to 660V, 0.1-80A power circuits, serving as full voltage starters to start and cut off the motor under AC3 load conditions.
Q What is the setting current range for the GV2P series?
The GV2P series accommodates setting current ranges from 0.1A up to 32A, depending on the specific model chosen (e.g., GV2P01 starting at 0.1-0.16A to GV2P32 up to 24.0-32.0A).
Q How does the GV3P series differ from the GV2P series?
While both provide overload and short circuit protection, the GV3P series covers higher rated powers and setting ranges, expanding the current carrying capabilities from 1.0A up to 80.0A (GV3P80 model).
Q Are these motor circuit breakers compatible with 3-phase motor configurations?
Yes, they are specifically rated for the standard power of 3-phase motors operating at 50/60Hz, covering standard operational voltages like 220V, 380V, 415V, 440V, 500V, and 660V.
Q Do these breakers provide short circuit protection for distribution networks?
Yes, in addition to direct motor protection, they can be utilized for overload and short circuit protection of circuits and power equipment within distribution networks.

Related Products