0219 Sjkw1 Air Circuit Breaker Certified, for Industrial Power Distribution

Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Energy-storage Type

Product Description

Overview & Basic Specs
Model NO. SJKW1-2000
Speed Normal Type
Medium Air
Installation Draw out / Fixed
Structure ACB
Poles Number 3p/4p
Type Circuit Breaker
Function Conventional CB
Certification ISO9001-2000, CE, CCC
Rated Current 200~6300A
Ue (V) 400/415, 660/690
Frequency 50/60Hz
Operating Cycles 2000-10000
Operating Voltage AC/DC
Power Required AC:220V/380V; DC:110/220V
Capacity 1000 Units/Week
Package Size 100.00cm * 80.00cm * 75.00cm
Package Gross Weight 8.000kg
Transport Package Wooden Cases
Specification 50.00cm * 40.00cm * 50.00cm
Product Description
SJKW1 Air Circuit Breaker
SJKW1 Intelligent Universal Circuit Breaker

The SJKW1 series is designed for 50Hz AC distribution networks (up to 660/690V, 200A-6300A). It distributes power while protecting against overload, undervoltage, short circuit, and single-phase grounding faults. Featuring intelligent protection and selective tripping, it improves power reliability and prevents unnecessary outages. With an open communication interface, it supports remote control for automation systems. Suitable for installations up to 2000m altitude (8000V pulse withstand voltage, adjustable to max 12000V). Without an intelligent controller/sensor, it can operate as an isolator.

Model and Meaning
SJK W 1 / [Frame Level Current] [Poles]
  • SJK: Enterprise code
  • W: Universal circuit breaker
  • 1: Design serial number
  • First Blank: Rated current of circuit breaker frame level
  • Second Blank: Number of poles: 4-pole marked as 4, no marking for 3-pole
Technical Drawings & Schematics
Technical Drawing 1
Technical Drawing 2
Technical Specifications
Circuit Breaker Operating Characteristics
Rated Current of Frame Level (A) Total Number of Operating Cycles
2000 10000
3200/4000 5000
6300 2000
Power Requirements for Releases & Mechanism AC (50Hz) DC
220V 380V 110V 220V
Shunt Release 24VA 36VA 24VA 24VA
Undervoltage Release 24VA 36VA - -
Closing Electromagnet 24VA 36VA 24VA 24VA
Motorized Mechanism (2000A Frame) 85VA 85VA 85VA 85VA
Motorized Mechanism (3200A/4000A Frame) 110VA 110VA 110VA 110VA
Motorized Mechanism (6300A Frame) 150VA 150VA 150VA 150VA
Intelligent Controller Supply Voltage: AC220V, AC380V, DC220V, DC110V
Note: Reliable operating range is 70%-110% for shunt release, and 80%-110% for closing electromagnet & operating mechanism.
Performance Data Table
Rated Current of Frame Level Inm (A) Rated Current In (A)
2000 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000
3200 2000, 2500, 2900, 3200
4000 3200, 3600, 4000
6300 4000, 5000, 6300
Schematics Detail A
Schematics Detail B
Schematics Detail C
Breaking Capacity Specs 1600A 2000A 3200A 4000A 6300A
Icu (kA) Ultimate Breaking Cap. 400/415V 65 80 100 120 135
660/690V 50 65 85 85 100
Ics (kA) Service Breaking Cap. 400/415V 55 65 80 100 135
660/690V 42 65 70 85 100
Icw (kA) 1s Short-time Withstand 400/415V 50 65 80 100 135
660/690V 42 65 70 85 100
Icm (kA) Making Capacity 400/415V 110 176 220 264 297
660/690V 77 143 154 187 220
Electrical Life (Cycles) 8000 8000 8000 6000 1500
Mechanical Life (With Maint.) 30000 30000 20000 20000 5000
Mechanical Life (No Maint.) 20000 15000 12500 10000 2500
Frequently Asked Questions
Q: What are the typical applications for your air circuit breakers (ACBs)?
A: Our ACBs are widely used as main incoming feeders, couplers, and large outgoing feeders in:
  • Industrial power distribution systems (factories, processing plants)
  • Commercial buildings (data centers, hospitals, shopping malls, hotels)
  • Infrastructure projects (ports, airports, power stations, substations)
  • Renewable energy systems (solar and wind farms)
Q: How do I select the right size (current rating) ACB for my application?
A: Selecting the correct current rating involves:
  • Calculating the total maximum continuous load current of the circuit.
  • Applying relevant derating factors (ambient temperature, enclosure, grouping).
  • Choosing an ACB with a Rated Current (In) equal to or higher than the calculated value.
Q: How do I ensure the ACB has sufficient breaking capacity (Icu/Ics) for my system?
A: The ACB's Ultimate Breaking Capacity (Icu) must be equal to or greater than the prospective short-circuit current at its installation point in your electrical network. This requires performing a short-circuit study of your system prior to installation.
Q: Can we print our logo or custom branding on products?
A: Yes, OEM customization is available. Please provide the size specifications and Pantone Color Code of the logo for custom marking.
Q: What is the typical lead time for a regular order?
A: For order quantities lower than 1000 pieces, the lead time is 7-15 days. For larger orders, it typically takes 20 days.
Q: Do you inspect the finished products before shipment?
A: Yes, each step of the production cycle and all finished products undergo rigorous quality control inspections by our QC department before dispatch.

Related Products